Cobalt Updates Sun Cobalt CacheRaQ4
Downloads MUST be applied from the bottom of the page to the top, as they must be applied in chronlogical order.
Application of these patches in improper order will likely result in problems with the Sun Cobalt product.
System Update 0.0.1
A few issues involving the Sun Cobalt CacheRaQ 4 appliance are resolved with this patch
- Configuring a cluster was not possible in some network topologies.
- Holding the password reset button on the front lcd panel did not reset the password
- Under some situations, the squid configuration file could be truncated. This would not allow squid to be able to run.
New init scripts will check to make sure that squid configuration is correct.
MD5 Check Sum: 109491eb91b0075197232df0cf697737
Reboot Required: Yes
telnetd Update 0.0.1
This security patch addresses an issue found in the telnet daemon, where a remote attacker is able to gain access to server
appliances
if telnet is enabled. Information regarding this update can be found at CERT Coordination Center's website. The URL is:
http://www.cert.org/advisories/CA-2001-21.html.
MD5 Check Sum: a1d644cfcb228e4be49756bb2cc4f887
Kernel Update 0.0.1
This Kernel Upgrade provides a complete fix for the sysctl negative offset bug as well as the ptrace setuid bug. Information
regarding this update can be found at Security Focus’ website. The URLs are:
http://www.securityfocus.com/vdb/?id=2364 - sysctl
bug
http://www.securityfocus.com/vdb/?id=2044 - ptrace bug
NOTE:
- The previous version of this update did not completely close the security holes mentioned above. It is strongly
recommended that users install the latest Kernel version.
A known issue with systems not being able to reboot completely has been fixed in this version. Once installation is
completed
the system should be powered down and back up so the new kernel can take effect.
MD5 Check Sum: 7308e0c3f9fd5d2fde7938822e8c1234
System Patch 0.0.1
This update corrects the following issues:
- Squid may not be able to respond to requests while under a high load circumstance which may result in the creation of
assertion errors in the error log.
- WCCP protocol 1 interoperability
- If more than one Sun Cobalt CacheRaQ appliance is part of a cluster one of the appliances may not be recognized.
- If client browser information is not received some sites do not display properly. To correct this a UI option was added
to allow the user to force the Sun Cobalt RaQ server appliance to pass browser information to the site it is requesting
information from.
MD5 Check Sum: b6cd8b94ed4d072fbde536d8a8c14060
proftpd Update 0.0.1
This package upgrades the version of proftpd to 1.2.0rc3.
|